Case ID from Davis is 10926
Green LED not lit on datalogger ethernet connector
Must shutdown, then enter setup mode
1. Press DONE and down arrow (- key)
2. Remove battery
3. Unplug Ethernet cable from router
4. Disconnect AC
5. Wait 2 minutes
6. Remove data logger module from console
7. Wait 2 minutes
8. Replace data logger
9. Reconnect AC
- wait for 1 beep, followed in about 10 seconds by 2 more beeps
10. Console will reset, showing Receiveing data from 1
11. Press done until date, time are OK
12. Press and hold DONE for 3 seconds
13. Display screen will show
14. Insert battery
15. Replace Ethernet cable
16. After about 2 minutes, flashing X will appear in right lower corner of console
17. Green LED on logger cable should light.
- If not, call Davis help with DID info from logger cable and case ID
18. Log on to weatherlink.com and setup account
19. If the DID on the logger is > EB7, the firmware should be OK
Instructions from Davis help desk 7-14-2009